Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 3.703
1.
Mikrochim Acta ; 191(6): 311, 2024 05 08.
Article En | MEDLINE | ID: mdl-38717575

Urine retinol-binding protein 4 (RBP4) has recently been reported as a novel earlier biomarker of chronic kidney disease (CKD) which is a global public health problem with high morbidity and mortality. Accurate and rapid detection of urine RBP4 is essential for early monitor of impaired kidney function and prevention of CKD progression. In the present study, we developed a time-resolved fluorescence immunochromatographic test strip (TRFIS) for the quantitative and rapid detection of urine RBP4. This TRFIS possessed excellent linearity ranging from 0.024 to 12.50 ng/mL for the detection of urine RBP4, and displayed a good linearity (Y = 239,581 × X + 617,238, R2 = 0.9902), with the lowest visual detection limit of 0.049 ng/mL. This TRFIS allows for quantitative detection of urine RBP4 within 15 min and shows high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 8%, respectively. Additionally, this TRFIS was applied to detect RBP4 in the urine samples from healthy donors and patients with CKD, and the results of TRFIS could efficiently discern the patients with CKD from the healthy donors. The developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range, and is suitable for rapid and quantitative determination of urine RBP4.


Chromatography, Affinity , Renal Insufficiency, Chronic , Retinol-Binding Proteins, Plasma , Humans , Retinol-Binding Proteins, Plasma/urine , Chromatography, Affinity/methods , Renal Insufficiency, Chronic/urine , Renal Insufficiency, Chronic/diagnosis , Limit of Detection , Reagent Strips , Biomarkers/urine , Immunoassay/methods
2.
Mikrochim Acta ; 191(6): 325, 2024 05 13.
Article En | MEDLINE | ID: mdl-38739279

Glial fibrillary acidic protein (GFAP) in serum has been shown as a biomarker of traumatic brain injury (TBI) which is a significant global public health concern. Accurate and rapid detection of serum GFAP is critical for TBI diagnosis. In this study, a time-resolved fluorescence immunochromatographic test strip (TRFIS) was proposed for the quantitative detection of serum GFAP. This TRFIS possessed excellent linearity ranging from 0.05 to 2.5 ng/mL for the detection of serum GFAP and displayed good linearity (Y = 598723X + 797198, R2 = 0.99), with the lowest detection limit of 16 pg/mL. This TRFIS allowed for quantitative detection of serum GFAP within 15 min and showed high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 4.0%. Additionally, this TRFIS was applied to detect GFAP in the serum samples from healthy donors and patients with cerebral hemorrhage, and the results of TRFIS could efficiently discern the patients with cerebral hemorrhage from the healthy donors. Our developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range and is suitable for rapid and quantitative determination of serum GFAP on-site.


Chromatography, Affinity , Glial Fibrillary Acidic Protein , Limit of Detection , Glial Fibrillary Acidic Protein/blood , Humans , Chromatography, Affinity/methods , Reagent Strips , Cerebral Hemorrhage/blood , Cerebral Hemorrhage/diagnosis , Biomarkers/blood
3.
Anal Methods ; 16(16): 2456-2463, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38591267

An elevated level of homocysteine (Hcy) in serum is closely related to the development of various diseases. Therefore, homocysteine has been widely employed as a biomarker in medical diagnosis and the on-site detection of homocysteine is highly desired. In this study, a truncated highly specific aptamer for homocysteine was screened and used to design a lateral flow strip (LFS) for the detection of homocysteine. The aptamer was derived from a previously reported sequence. Based on the result of molecular docking, the original sequence was subjected to truncation, resulting in a reduction of the length from 66 nt to 55 nt. Based on the truncated aptamer, the LFS was designed for the detection of homocysteine. In the presence of homocysteine, the aptamer selectively binds to it, releasing cDNA from the aptamer/cDNA duplex. This allows cDNA to bind to the capture probe immobilized on the T zone of the strip, resulting in a red signal on the T zone from gold nanoparticles (AuNPs). The strip enables the visual detection of homocysteine in 5 min. Quantitative detection can be facilitated with the aid of ImageJ software. In this mode, the linear detection range for homocysteine is within 5-50 µM, with a detection limit of 4.18 µM. The strip has been effectively utilized for the detection of homocysteine in human serum. Consequently, the combination of the truncated aptamer and the strip offers a method that is sensitive, quick, and economical for the on-site detection of homocysteine.


Aptamers, Nucleotide , Gold , Homocysteine , Metal Nanoparticles , Homocysteine/blood , Homocysteine/chemistry , Homocysteine/analysis , Aptamers, Nucleotide/chemistry , Humans , Gold/chemistry , Metal Nanoparticles/chemistry , Limit of Detection , Biosensing Techniques/methods , Reagent Strips/chemistry , Molecular Docking Simulation
4.
Analyst ; 149(9): 2747-2755, 2024 Apr 29.
Article En | MEDLINE | ID: mdl-38563739

Avian leukemia is an infectious tumorous disease of chickens caused by subgroup A of the avian leukemia virus (ALV-A), which mainly causes long-term viremia, slow growth, immune suppression, decreased production performance, multi-tissue tumors, and even death. The infection rate of this disease is very high in chicken herds in China, causing huge economic losses to the poultry industry every year. We successfully expressed the specific antigen protein of ALV (P27) through recombinant protein technology and screened a pair of highly sensitive monoclonal antibodies (mAbs) through mouse immunity, cell fusion, and antibody pairing. Based on this pair of antibodies, we established a dual antibody sandwich ELISA and gold nanoparticle immunochromatographic strip (AuNP-ICS) detection method. In addition, the parameters of the dual antibody sandwich ELISA and AuNP-ICS were optimized under different reaction conditions, which resulted in the minimum detection limits of 0.2 ng mL-1 and 1.53 ng ml-1, respectively. Commonly available ELISA and AuNP-ICS products on the market were compared, and we found that our established immune rapid chromatography had higher sensitivity. This established AuNP-ICS had no cross-reactivity with Influenza A (H1N1), Influenza A (H9N2), respiratory syncytial virus (RSV), varicella-zoster virus (VZV), Listeria monocytogenes listeriolysin (LLO), and Staphylococcal enterotoxin SED or SEC. Finally, the established AuNP-ICS was used to analyze 35 egg samples, and the results showed 5 positive samples and 30 negative samples. The AuNP-ICS rapid detection method established by our group had good specificity, high sensitivity, and convenience, and could be applied to the clinical sample detection of ALV-A.


Avian Leukosis Virus , Chromatography, Affinity , Enzyme-Linked Immunosorbent Assay , Gold , Metal Nanoparticles , Gold/chemistry , Metal Nanoparticles/chemistry , Animals , Avian Leukosis Virus/isolation & purification , Avian Leukosis Virus/immunology , Chromatography, Affinity/methods , Enzyme-Linked Immunosorbent Assay/methods , Antigens, Viral/immunology , Antigens, Viral/analysis , Egg White/chemistry , Reagent Strips , Chickens , Limit of Detection , Mice , Antibodies, Monoclonal/immunology , Antibodies, Monoclonal/chemistry
5.
Molecules ; 29(8)2024 Apr 13.
Article En | MEDLINE | ID: mdl-38675595

The COVID-19 pandemic over recent years has shown a great need for the rapid, low-cost, and on-site detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this study, an aptamer-based colloidal gold nanoparticle lateral flow test strip was well developed to realize the visual detection of wild-type SARS-CoV-2 spike proteins (SPs) and multiple variants. Under the optimal reaction conditions, a low detection limit of SARS-CoV-2 S proteins of 0.68 nM was acquired, and the actual detection recovery was 83.3% to 108.8% for real-world samples. This suggests a potential tool for the prompt detection of SARS-CoV-2 with good sensitivity and accuracy, and a new method for the development of alternative antibody test strips for the detection of other viral targets.


Aptamers, Nucleotide , COVID-19 , Gold , Metal Nanoparticles , SARS-CoV-2 , Spike Glycoprotein, Coronavirus , SARS-CoV-2/isolation & purification , Metal Nanoparticles/chemistry , Gold/chemistry , Aptamers, Nucleotide/chemistry , Humans , COVID-19/diagnosis , COVID-19/virology , Limit of Detection , Reagent Strips
6.
Lancet Microbe ; 5(4): e366-e378, 2024 Apr.
Article En | MEDLINE | ID: mdl-38467130

BACKGROUND: Accurate diagnosis is pivotal for implementing strategies for surveillance, control, and elimination of schistosomiasis. Despite their low sensitivity in low-endemicity areas, microscopy-based urine filtration and the Kato-Katz technique are considered as reference diagnostic tests for Schistosoma haematobium and Schistosoma mansoni infections, respectively. We aimed to collate all available evidence on the accuracy of other proposed diagnostic techniques. METHODS: In this systematic review and meta-analysis, we searched PubMed, Embase, the Cochrane Library, and LILACS for studies published from database inception to Dec 31, 2022, investigating the sensitivity and specificity of diagnostic tests for S haematobium and S mansoni infections against Kato-Katz thick smears or urine microscopy (reference tests) involving adults (aged ≥18 years), school-aged children (aged 7 to 18 years), or preschool-aged children (aged 1 month to 7 years). We extracted raw data on true positives, true negatives, false positives, and false negatives for the diagnostic tests and data on the number of participants, study authors, publication year, journal, study design, participants' age and sex, prevalence of Schistosoma infection, and treatment status. To account for imperfect reference tests, we used a hierarchical Bayesian latent class meta-analysis to model test accuracy. FINDINGS: Overall, we included 121 studies, assessing 28 different diagnostic techniques. Most studies (103 [85%] of 121) were done in Africa, 14 (12%) in South America, one (1%) in Asia, and one (1%) in an unknown country. Compared with the reference test, Kato-Katz thick smears, circulating cathodic antigen urine cassette assay version 1 (CCA1, 36 test comparisons) had excellent sensitivity (95% [95% credible interval 88-99]) and reasonable specificity (74% [63-83]) for S mansoni. ELISA-based tests had a performance comparable to circulating cathodic antigen, but there were few available test comparisons. For S haematobium, proteinuria (42 test comparisons, sensitivity 73% [62-82]; specificity 94% [89-98]) and haematuria (75 test comparisons, sensitivity 85% [80-90]; specificity 96% [92-99]) reagent strips showed high specificity, with haematuria reagent strips having better sensitivity. Despite limited data, nucleic acid amplification tests (NAATs; eg, PCR or loop-mediated isothermal amplification [LAMP]) showed promising results with sensitivity estimates above 90%. We found an unclear risk of bias of about 70% in the use of the reference or index tests and of 50% in patient selection. All analyses showed substantial heterogeneity (I2>80%). INTERPRETATION: Although NAATs and immunological diagnostics show promise, the limited information available precludes drawing definitive conclusions. Additional research on diagnostic accuracy and cost-effectiveness is needed before the replacement of conventional tests can be considered. FUNDING: WHO and Luxembourg Institute of Health.


Schistosoma mansoni , Schistosomiasis haematobia , Child , Child, Preschool , Adult , Animals , Humans , Adolescent , Schistosoma haematobium , Hematuria/diagnosis , Reagent Strips , Microscopy , Bayes Theorem , Feces , Antigens, Helminth/urine , Urinalysis , Schistosomiasis haematobia/diagnosis , Diagnostic Tests, Routine/methods
7.
Methods ; 224: 63-70, 2024 Apr.
Article En | MEDLINE | ID: mdl-38367653

Urinalysis is a useful test as an indicator of health or disease and as such, is a part of routine health screening. Urinalysis can be undertaken in many ways, one of which is reagent strips used in the general evaluation of health and to aid in the diagnosis and monitoring of kidney disease. To be effective, the test must be performed properly, and the results interpreted correctly. However, different light conditions and colour perception can vary between users leading to ambiguous readings. This has led to camera devices being used to capture and generate the estimated biomarker concentrations, but image colour can be affected by variations in illumination and inbuilt image processing. Therefore, a new portable device with embedded image processing techniques is presented in this study to provide quantitative measurements that are invariant to changes in illumination. The device includes a novel calibration process and uses the ratio of RGB values to compensate for variations in illumination across an image and improve the accuracy of quantitative measurements. Results show that the proposed calibration method gives consistent homogeneous illumination across the whole image. Comparisons against other existing methods and clinical results show good performance with a correlation to the clinical values. The proposed device can be used for point-of-care testing to provide reliable results consistent with clinical values.


Point-of-Care Systems , Reagent Strips , Urinalysis/methods , Image Processing, Computer-Assisted
8.
J Pharm Biomed Anal ; 242: 115976, 2024 May 15.
Article En | MEDLINE | ID: mdl-38350371

Lung cancer is the most common malignancy worldwide. Early diagnosis helps to reduce mortality and improve survival. Aptamers are widely used in cancer screening because of their high specificity, good stability and low cost. In this study, using the specific aptamer of lung cancer serum, the sandwich method colloidal gold test strip was prepared by isothermal amplification technique and the principle of nucleic acid hybridisation for the early diagnosis of lung cancer. The results showed that the test strip was positive in 8 patients with lung cancer, which was consistent with the actual cases. The test strip can accurately identify lung cancer patients. The concentration range of nucleic acid detection is 1 × 10-4 - 7 × 10-4 mol/L, and the detection limit is 0.67 mM. The test strip detection method has low cost and simple operation, and provides a reference for the development of home portable tumor early detection.


Aptamers, Nucleotide , Lung Neoplasms , Nucleic Acids , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/genetics , Early Detection of Cancer , Nucleic Acid Hybridization , Reagent Strips
10.
Arch Pathol Lab Med ; 148(4): e69-e74, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-37852173

CONTEXT.­: Urinalysis instrument-specific dip strips offer physicians qualitative results for actionable analytes (protein, glucose, leukocyte esterase, nitrates, hemoglobin, and ketones). OBJECTIVE.­: To explain a strategy implemented to support clinical decision-making by providing urine quantification of protein, glucose, white blood cells (WBCs), and red blood cells because of urine strip shortages. DESIGN.­: During shortages, we implemented an automated algorithm that triggered sending urine samples to the automation line for quantification of protein and glucose and ensured that urine microscopy was performed to obtain WBC and red blood cell counts. The algorithm printed 2 labels so nursing staff would collect 2 specimens. We monitored the turnaround time from the specimen being received in the laboratory to result verification, ensured that the culture reflex order was triggered, and tracked complaints by physicians regarding not having usual urinalysis results. Prior to implementation, correlation between sample types for protein and glucose measurement was found acceptable. RESULTS.­: The algorithm was put in place twice during 2022. The turnaround time of urine microscopic study was identical to that obtained when the urinalysis was done with the strips; however, the quantification of glucose and protein took approximately 30 minutes more. Urine reflex cultures were triggered correctly with the algorithm, as they were derived entirely from a WBC count higher than 10 per high-power field. During the shortage period we had only 1 complaint, by a physician wanting to have results of nitrates. CONCLUSIONS.­: During urine strip shortages, we successfully implemented a diversion algorithm that provided actionable urinalysis analytes in a timely manner with minimal provider complaints.


Microscopy , Urinalysis , Humans , Urinalysis/methods , Hemoglobins , Glucose , Nitrates , Reagent Strips , Leukocyte Count
11.
Cornea ; 43(5): 635-640, 2024 May 01.
Article En | MEDLINE | ID: mdl-38015937

PURPOSE: Schirmer test results are widely used for ocular surface disease assessment, but Schirmer strips are not standardized. We compare the characteristics and tear volume with millimeter moisture migration in different brands of Schirmer strips and introduce methods for volume-based, brand-independent calibration. METHODS: Physical parameters of Haag-Streit, EagleVision, TearFlo, Contacare, and MIPL/A6 Schirmer strip brands were compared. Schirmer strip millimeter moisture migration distances were assessed 5 minutes after application of incremental microliter volumes of human tears. Linear regression analysis of data points from each Schirmer strip brand was performed, and the root-mean-square deviation of data points to the best-fit linear regression was calculated. Calibration correction was performed by converting migration distance to the corresponding tear volume. A reference table and calibration method formulas were created. RESULTS: Schirmer strips differed in design, shape, and manufacturing precision. Strip width, weight, and length were different between the 5 brands ( P < 0.05). A wide range of Schirmer strip moisture migration values for identical tear volumes was observed among brands. Statistical measurement resulted in a root-mean-square deviation of 2.9 mm for all data points from all brands. Millimeter to volume and weight to volume-based calibration correction methods resulted in a 2.2- and 3.1-fold measurement error reduction, respectively. CONCLUSIONS: Our findings highlight the lack of standardization among different brands of Schirmer strips, raising concerns about potential sources of unintentional measurement errors. We propose volume-based Schirmer strip calibration methods and conversion of millimeter to microliter results to achieve brand-independent results and improve Schirmer test accuracy.


Lacerations , Reagent Strips , Humans , Calibration , Tears , Reference Standards
12.
Stud Health Technol Inform ; 308: 168-178, 2023 Nov 23.
Article En | MEDLINE | ID: mdl-38007738

In this study, monoclonal antibodies against oxamyl were prepared, and colloidal gold immunochromatography was used to design a rapid test strip product for the detection of oxamyl in tobacco with high specificity, accuracy and stability without cross-reactivity to commonly used tobacco fungicides based on the optimization of conditions such as pH value of diluent, diluent dosage, concentration of antibody marker, type of confining solution and complex solution. 5 The results of five samples of post-harvest ready-to-bake tobacco and first-harvest tobacco were consistent with the gas chromatographic method, which proved the reliability of the test strips. The limits of detection for the post-harvest and first-harvest tobacco samples were 0.1 mg/kg, and the test strips developed in this study are suitable for mass testing in tobacco laboratories with good application prospects because of their short detection time, simple pre-treatment and detection methods.


Nicotiana , Reagent Strips , Reagent Strips/analysis , Reproducibility of Results , Gold Colloid/chemistry , Sensitivity and Specificity
13.
Stud Health Technol Inform ; 308: 179-190, 2023 Nov 23.
Article En | MEDLINE | ID: mdl-38007739

The rapid and accurate determination of triadimenol residues is of great significance. In this study, based on the advantages of high efficiency, rapidity, reliability, simplicity and low cost of immunology, a test strip product for the rapid detection of triadimenol residues in tobacco was designed based on the optimization of conditions such as pH and dosage of diluent, concentration of antibody stock solution, type of confining solution and complex solution, with high specificity, accuracy and The results of 20 samples of fresh and first roasted tobacco were all consistent with the method of gas chromatography, which proved the reliability of the test strips. The detection limit for fresh and roasted tobacco was 5 mg/kg, and the test strips developed in this study are suitable for mass testing of tobacco samples in tobacco-related laboratories because of their short detection time, simple pre-treatment and detection methods, and good application prospects.


Nicotiana , Reagent Strips , Reagent Strips/analysis , Reproducibility of Results , Gold Colloid/chemistry , Sensitivity and Specificity
14.
Clin Chim Acta ; 550: 117534, 2023 Oct 01.
Article En | MEDLINE | ID: mdl-37739023

INTRODUCTION: Urinalysis is essential for diagnosing kidney-related medical conditions. Urine test strip analysis serves as an initial and efficient screening method for reflex testing with accurate quantitative methods. MATERIALS AND METHODS: Freshly voided urines (n = 206) were analysed using two urine test strip brands on UC-MAX (Menarini) and cobas u 601 (Roche Diagnostics) instruments. Ordinal scale categories and reflectance signals (if available) were both used for the comparison with reference quantitative methods for glucose, proteins and albumin (cobas 503). Samples were considered positive when glucose > 15 or ≥ 54 mg/dL, proteins ≥ 200 mg/L and albumin ≥ 10 mg/L. Optimized reflectance thresholds were calculated by ROC curve analysis. Analytical performance specifications (APS) for trueness of test strip were gathered from the EFLM guideline (FPD, FNG, FNC). RESULTS: Reflectance signals were significantly lower in urine samples considered positive by the reference method (p < 0.0001). Reflectance signals were also correlated with quantitative measurements, showing strong correlation (0.754 to 0.969). Only the use of optimized reflectance thresholds on cobas u 601 achieved at least the minimum EFLM APS (FPD < 20%, FNG < 50% and FNC < 10%). CONCLUSION: The use of reflectance signals from urine test strips enhanced accuracy for glucose, proteins, and albumin measurement and may contribute to improve diagnosis of diverse kidney-related conditions.


Reagent Strips , Urinalysis , Humans , Urinalysis/methods , Glucose/analysis , Proteins , Albumins
15.
Clin Chim Acta ; 548: 117500, 2023 Aug 01.
Article En | MEDLINE | ID: mdl-37500032

BACKGROUND: To address the situation that the accuracy of concentration intervals (CI) corresponding to dipstick grades is not given by the manufacturers or literature, we developed a method that determined reasonable dipstick grades with concentration intervals (GCIs) based on the percent agreement (PA) and discussed the GCI application to comparability among currently dipstick tests. METHODS: By comparing the results of 2 dipstick tests (iChem and KU-500) with the quantitative test (AU5800), the GCIs were verified and established based on the PAs, which were calculated and used as an indicator of GCI's accuracy. The overlap (percent) between the 2 GCIs with the same grade (2 dipstick devices), was calculated and used to evaluate the agreement between their test results. RESULTS: After verification and adjustment, the GCI and PA combinations for iChem Velocity were as follows: - (<0.1 g/l, 85 %), ± (0.1-0.3 g/l, 66 %), 1+ (0.3-1 g/l, 78 %), 2+ (1-3 g/l, 74 %), 3+ (3-6 g/l, 77 %), and 4+ (≥6 g/l, 84 %). The determined GCI and PA combinations for KU-500 were: - (<0.1.2 g/l, 75 %), ± (0.12-0.5 g/l, 63 %), 1+ (0.5-1.2 g/l, 69 %), 2+ (1.2-3.2 g/l, 76 %), and 3+ (≥3.2 g/l, 82 %). The GCI overlaps between the 2 dipstick devices were - (83 %), ± (45 %), 1+ (56 %), 2+ (82 %), and 3+ or ≥3+ (94 %). The overall overlap was 72 %. Since the overlaps ± (45 %) and 1+ (56 %) were within the overlap reject limit for any grade (70 %), and the overall overlap (72 %) was within the overall overlap reject limit (80 %), the test results of the 2 devices were not comparable. CONCLUSIONS: GCIs can be verified and established correctly based on PAs, and industry standards for dipstick tests can be established based on GCIs and PAs. Comparability between dipstick devices, historical data, and literature data can be roughly determined based on the overlap.


Reagent Strips , Urinalysis , Humans , Sensitivity and Specificity , Urinalysis/methods
16.
J Vet Diagn Invest ; 35(5): 492-499, 2023 Sep.
Article En | MEDLINE | ID: mdl-37326167

Standard visual urine dipstick analysis (UDA) is performed routinely in veterinary medicine; results can be influenced by both the operator and the method. We evaluated the agreement of results for canine and feline urine samples analyzed using a 10-patch dipstick (Multistix10SG; Siemens), both visually under double-anonymized conditions by students and a laboratory technician, and with an automated device (AD; Clinitek Status, Siemens). The mean concordance for semiquantitative urinalysis results between students and the technician and between students and the AD was fair (κ0.21-0.40) in dogs and cats; concordance was moderate between the technician and the AD (κ0.41-0.60) in dogs and good (κ0.61-0.80) in cats. For pH, the mean concordance between students and the technician and between the technician and the AD was good (ρ0.80-0.92) in dogs and cats; concordance was good between students and the AD (ρ0.80-0.92) in dogs and moderate (ρ0.59-0.79) in cats. Repeatability was higher (p < 0.001) for the technician and the AD than for a student. We found good agreement between UDA performed by an experienced operator and an AD in dogs and cats but found low reproducibility and low repeatability for urinalysis performed by an inexperienced operator.


Cat Diseases , Dog Diseases , Urinalysis , Cats , Dogs , Animals , Cat Diseases/diagnosis , Cat Diseases/urine , Reproducibility of Results , Observer Variation , Dog Diseases/diagnosis , Dog Diseases/urine , Reagent Strips , Urinalysis/methods , Urinalysis/veterinary
17.
J Assoc Physicians India ; 71(1): 1, 2023 Jan.
Article En | MEDLINE | ID: mdl-37116047

INTRODUCTION: Spontaneous bacterial peritonitis (SBP) is a common and serious complication in cirrhosis patients with an incidence and mortality of about 30% and 25% respectively in hospitalised patients. Currently the diagnostic criteria is presence of >250 neutrophils per microlitre in ascitic fluid, but these facilities are not available at all timings and often the results are delayed. A rapid and bedside test is needed for diagnosis of SBP which aids in timely treatment.Dipsticks based on detection of leukocyte esterase in fluid are available everywhere and widely used for detecting urinary tract infection. In this study we aimed to find out the diagnostic utility of these dipsticks in SBP for immediate diagnosis. MATERIALS: An observational cross sectional study was conducted among 75 patients with cirrhosis suspected of having SBP clinically. Relevant investigations, diagnostic paracentesis and dipstick test of ascitic fluid was done. The patients were divided into two groups with and without SBP.The ascitic fluid neutrophil count and dipstick results were compared in both groups. RESULT: 26 patients (34.6%) had SBP out of total 75 patients. AKI and hepatic encephalopathy were significantly higher in SBP patients (53% and 50% respectively in SBP patients; 28% and 18% in patients without SBP). Sensitivity and specificity of dipstick test with cutoff of more than 1+ was 96% and 75% respectively; with cutoff of more than 2 was 80% and 91% respectively. CONCLUSION: The dipstick can be used as a bedside maneuver for immediate diagnosis of SBP. Having a good negative predictive value, it can also be used to exclude SBP, thus avoiding unnecessary antibiotics administration. References Koulaouzidis A. Diagnosis of spontaneous bacterial peritonitis: an update on leucocyte esterase reagent strips. World J Gastroenterol 2011;17(9):1091-1094. Oey RC, Kuiper JJ, Van Buuren HR, et al. Reagent strips are efficient to rule out spontaneous bacterial peritonitis in cirrhotics. Neth J Med 2016;74(6):257-261.


Bacterial Infections , Peritonitis , Humans , Reagent Strips , Cross-Sectional Studies , Bacterial Infections/complications , Ascitic Fluid/microbiology , Peritonitis/etiology , Peritonitis/microbiology , Liver Cirrhosis/complications , Liver Cirrhosis/diagnosis
18.
Sci Rep ; 13(1): 4433, 2023 03 17.
Article En | MEDLINE | ID: mdl-36932139

Tear fluid forms a potential source for biomarker identification, and can be minimal invasively collected via Schirmer strips. The lack of knowledge on the processing of Schirmer strips however complicates the analysis and between-study comparisons. We studied two different pre-processing methods, specifically the use of punches of the strip versus elution of the strip in a buffer. Tear fluid filled Schirmer strips were collected from 5 healthy participants, and divided into two halves over the length of the strip. In either part, punches or eluates were obtained from 4 different locations, from the first part touching the eye (head) to the end, to assess the protein distribution along the strips. The levels of 92 inflammatory proteins were measured in the punches/eluates using proximity extension assays. The punch method yielded higher protein detectability compared to the elution method (76% vs 66%; p ≤ 0.001). Protein expression level was found to be slightly higher in the head of the strip, however, 3 out of 5 punches from the head failed quality control. Protein expression levels over the remaining parts of the strips were similar. Our study showed beneficial use of punches of any part of the strip except the head in future biomarker research.


Proteomics , Reagent Strips , Humans , Tears/metabolism , Proteins/metabolism , Biological Assay
19.
Analyst ; 148(6): 1246-1252, 2023 Mar 13.
Article En | MEDLINE | ID: mdl-36806350

In the face of complex public health emergencies and various social medical needs in new situations, it is urgent to establish rapid detection technology for the early detection of pathogens to control their spread and minimize the resultant health and societal impact. Point-of-care testing (POCT) that allows rapid, on-site, and affordable detection and monitoring of health conditions at home or away from clinical labs has received increasing attention in modern medicine. In this work, we have synthesized multifunctional magainin I-human chorionic gonadotropin (hCG)-Cu3(PO4)2 nanoflowers and demonstrated a new strategy for the fast diagnosis of pathogenic microorganisms by combining functional nanoflowers with a lateral flow immunoassay device. The prepared multifunctional nanoflowers immobilized many signal molecules, which solves the poor sensitivity of traditional lateral flow strips and realizes the highly sensitive detection of pathogenic microorganisms ("accurate detection"). Besides, this method can complete the rapid transformation of commercial-off-the-shelf lateral flow strips and realize the fast diagnosis of target analytes in case of an outbreak ("fast detection"). Therefore, the established rapid and highly sensitive lateral flow immunoassay for the detection of pathogenic microorganisms will effectively improve the early diagnosis efficiency of infectious diseases caused by pathogenic microorganisms and shorten the diagnosis time of diseases.


Chorionic Gonadotropin , Point-of-Care Testing , Humans , Immunoassay/methods , Reagent Strips
20.
J Med Microbiol ; 72(2)2023 Feb.
Article En | MEDLINE | ID: mdl-36762527

Urinary tract infection (UTI) is one of the most common bacterial infections among humans. Urine culture is the gold standard diagnostic method for UTI; however, the dipstick test for nitrite is a widely used method signalling the presence of urinary nitrate-reducing bacteria. Unlike the gold standard, the dipstick test is easy to perform, while it is also less time-consuming and less expensive, and produces a result in a few minutes. This study investigates the sensitivity of the dipstick test for nitrite compared with the Griess test in urine samples from UTI caused by Enterobacterales species. We used the Griess test, which is the gold standard in nitrite measurement, to determine the sensitivity of the nitrite dipstick test. Semiquantitative urine culture was performed using standard procedures, and Enterobacterales identification was performed by manual conventional biochemical tests. In the first sample selection, 3 % (8/267) of urine samples suspected of UTI, analysed from March to April 2016, were nitrite-negative by dipstick test but positive for Enterobacterales in the urine culture. In the second sample selection, 5 % (2/44) of urine samples from October to December 2022 were also nitrite-negative but showed urine Enterobacterales isolation. All nitrite-negative dipstick results were consistent with the Griess test. Escherichia coli was the most prevalent bacterium, followed by Klebsiella pneumoniae, independent of sample selection. The dipstick test is a safe alternative for investigating nitrite in urine samples. We believe that the cause of nitrite-negative results is a lack of dietary nitrate, dilution of urine and exogenous interference (e.g. ascorbic acid). These findings support the idea that standard urine culture is necessary to rule out UTI.


Nitrites , Urinary Tract Infections , Humans , Nitrites/urine , Nitrates , Negative Results , Sensitivity and Specificity , Reagent Strips , Urinary Tract Infections/diagnosis , Urinary Tract Infections/microbiology , Urinalysis/methods , Escherichia coli
...